當前位置:首頁-資訊中心>公司新聞供水標識樁間距及埋設注意事項

供水標識樁間距及埋設注意事項

來源:http://m.yncls.com/ 發(fā)布時間:日期:2022-11-03 0
標識樁是經(jīng)常用于電力電纜鋪設、通信光纜、燃氣管道、農(nóng)田水利、鐵路、石油石化管線通道指示標志兼警告牌;也經(jīng)常用于鬧市、風景區(qū)、綠化帶、灌木叢、頂管兩側管線路徑指示起到警示作用,因此正確是埋設標識樁可使用更長時間,更好的警示作用。
The signpost is often used as an indicator and warning sign for power cable laying, communication optical cable, gas pipeline, farmland water conservancy, railway, petroleum and petrochemical pipeline channel; It is also often used in downtown areas, scenic spots, green belts, bushes, and pipeline route indication on both sides of pipe jacking to serve as a warning. Therefore, it is correct to bury marker piles to serve a longer time and better warning.
供水標識樁設置注意事項:
Precautions for water supply sign pile setting:
1、標識樁放置在管位上方,表面要求清潔、字跡清楚,如果不再管線上方,并說明平移距離。埋設在低于40cm綠化帶中,長樁埋設在高于40cm綠化帶或農(nóng)田中。
1. The marking pile shall be placed above the pipe position, and the surface shall be clean and legible. If it is no longer above the pipeline, the translation distance shall be stated. Buried in the green belt less than 40cm, and the long pile is buried in the green belt or farmland more than 40cm.
2.標識樁一般間距為50m(縱向偏差≯0.15m),與管位中心線偏差≯0.25m。
2. Generally, the spacing of marker piles is 50m (longitudinal deviation ≯ 0.15 m), and the deviation from the centerline of the pipe position is ≯ 0.25 m.
供水標識樁
3.在管道起點、終點、三通、轉角處須設置標記管線走向方便辨別。
3. The starting point, end point, tee joint and corner of the pipeline must be marked with the pipeline route for easy identification.
4、標識樁上面的警示語和電話須朝馬路放置或人經(jīng)過時及時能看到的方位。
4. The warning words and telephone on the sign post must be placed towards the road or be visible when people pass by.
☆警示牌的設置和標識樁設置類似
☆ The setting of warning signs is similar to that of signposts
供水標識樁的編號規(guī)定
Numbering regulations for water supply marker piles
如果設計到采用編號方式的,有各個企業(yè)自己的編號方式或者一般情況下項目編號前6位數(shù)字加三位數(shù)順序號組成。采用5cm高紅色宋體字寫于樁上。新建工程需在竣工圖上注明樁位臵及編號,在竣工圖左下角分別注明標識樁與標志牌總的數(shù)量。
If it is designed to adopt the numbering method, it is composed of the numbering method of each enterprise or the first six digits of the project number plus the three digit sequence number. It is written on the pile in 5cm high red Song typeface. For new projects, the pile location and number shall be indicated on the as built drawing, and the total number of identification piles and signboards shall be indicated on the lower left corner of the as built drawing.
管道設置要求
Pipeline setting requirements
當兩根管道平行鋪設且水平間距在0.4米1米時,除在每根管線上方相應標記牌或豎標記樁外,需在較短管線的標記牌或標記樁上標記字母“G,Z,D”.其中G代表管線為高壓管線、Z代表管線為中壓管線、D代表管線為低壓管線。標記牌上字母高度為1cm,標識樁上字母寫在樁編號下方,字母高度與樁編號高度相同。
When two pipelines are laid in parallel and the horizontal spacing is 0.4 m to 1 m, the letters "G, Z, D" shall be marked on the signboard or marker pile of the shorter pipeline, except for the corresponding signboard or vertical marker pile above each pipeline Where, G represents high pressure pipeline, Z represents medium pressure pipeline, and D represents low pressure pipeline. The letter height on the sign board is 1cm, and the letter on the marker pile is written below the pile number. The letter height is the same as the pile number.
供水標識樁間距及埋設注意事項就是上述所講解的內(nèi)容了,希望能夠給您好的幫助,當然如果您有什么疑惑的話隨時來我們網(wǎng)站http://m.yncls.com進行咨詢了解吧!